LEONARD TM-30, TM-50, TM-80, TM-125
AND TM-150 SHOWER VALVES |
|
LEONARD TM-30, 50, 80, 125, AND 150 |
ITEM |
DESCRIPTION |
1 |
Snap cap |
2 |
Pointer screw w/ washer |
3 |
Pointer |
4 |
Dial plate |
5 |
Friction spring |
6 |
Stop |
7 |
Cover |
8 |
Thermostat group |
9 |
Coil sleeve stud |
10 |
Pointer rod |
11 |
O-ring (2 required) |
12 |
Dial plate |
13 |
Port sleeve nut assembly |
14 |
Port sleeve assembly |
15 |
Flange packing |
16 |
Cover screws |
| |
| LEONARD PACKING & GASKET
KIT 1 |
 |
LEONARD
PACKING & GASKET KIT 1 |
ITEM |
DESCRIPTION |
1 |
O-Ring |
2 |
Lower stem & packing |
3 |
Flange packing |
4 |
Upper stem o-ring |
5 |
Cap packing |
6 |
Screen |
7 |
Bonnet packing |
Items 1-8 for
TM-30, TM-50 or TM-80 Part # 31414030 |
Items 1-8 for
TM-125 or TM-150 Part # 31414125 |
|
| |
| LEONARD REBUILDING KIT R |
 |
LEONARD REBUILDING KIT R |
ITEM |
DESCRIPTION |
1 |
Port sleeve nut assembly |
2 |
Coil sleeve stud |
3 |
Pointer rod |
4 |
Pointer rod o-rings |
5 |
Port sleeve assembly |
6 |
Thermostat group |
7 |
Flange packing |
Items 1-7 for TM-30 Part # 31413080 |
|
Items 1-7 for TM-50 or TM 80 Part # 31415080 |
|
Items 1-8 for TM-125 or TM-150 Part # 31413125 |
|
| |
| LEONARD CHECKSTOP KIT 2 |
 |
LEONARD CHECKSTOP KIT 2 |
ITEM |
DESCRIPTION |
1 |
Bonnet packing |
2 |
Lower stem & packing |
3 |
Spring |
4 |
Stem o-ring |
5 |
Screen |
6 |
Cap packing |
Items 1-6 for TM-30, TM-50 or TM-80 Part #
31415050 |
|
Items 1-6 for TM-125 or TM-150 Part # 31415125 |
|
| TROUBLESHOOTING INSTRUCTION |
PACKING & GASKETS |
Problem |
Parts Required |
Leak at pointer rod. |
Kit 1 |
Leak between valve cover and base. |
|
| |
PORT SLEEVE ASSEMBLY |
Problem |
Parts Required |
Valve delivers either all hot or all cold water,
or will not mix consistently. |
Port sleeve assembly or Rebuilding Kit R |
| |
THERMOSTAT GROUP |
Problem |
Parts Required |
After cleaning or replacing port sleeve assembly,
valve will not hold temperature. |
Thermostat group or Rebuilding Kit R |
| |
CHECKSTOPS |
Problem |
Parts Required |
Hot water bypass into cold line. |
Kit 2 |
Supplies cannot be shut off completely. |
Leak at checkstop bonnet. |
|
|
|
|
|